Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Int J Environ Res Public Health ; 20(5)2023 02 28.
Article in English | MEDLINE | ID: covidwho-2253939

ABSTRACT

Improving the cleaning and disinfection of high-touch surfaces is one of the core components of reducing healthcare-associated infections. The effectiveness of an enhanced protocol applying UV-C irradiation for terminal room disinfection between two successive patients was evaluated. Twenty high-touch surfaces in different critical areas were sampled according to ISO 14698-1, both immediately pre- and post-cleaning and disinfection standard operating protocol (SOP) and after UV-C disinfection (160 sampling sites in each condition, 480 in total). Dosimeters were applied at the sites to assess the dose emitted. A total of 64.3% (103/160) of the sampling sites tested after SOP were positive, whereas only 17.5% (28/160) were positive after UV-C. According to the national hygienic standards for health-care setting, 9.3% (15/160) resulted in being non-compliant after SOP and only 1.2% (2/160) were non-compliant after UV-C disinfection. Operation theaters was the setting that resulted in being less compliant with the standard limit (≤15 colony-forming unit/24 cm2) after SOP (12%, 14/120 sampling sites) and where the UV-C treatment showed the highest effectiveness (1.6%, 2/120). The addition of UV-C disinfection to the standard cleaning and disinfection procedure had effective results in reducing hygiene failures.


Subject(s)
Cross Infection , Robotics , Humans , Disinfection/methods , Xenon , Hospitals , Ultraviolet Rays
2.
Pathogens ; 10(8)2021 Aug 12.
Article in English | MEDLINE | ID: covidwho-1369783

ABSTRACT

A viral spread occurrence such as the SARS-CoV-2 pandemic has prompted the evaluation of different disinfectants suitable for a wide range of environmental matrices. Chlorine dioxide (ClO2) represents one of the most-used virucidal agents in different settings effective against both enveloped and nonenveloped viruses. This narrative synthesis is focused on the effectiveness of ClO2 applied in healthcare and community settings in order to eliminate respiratory transmitted, enteric, and bloodborne viruses. Influenza viruses were reduced by 99.9% by 0.5-1.0 mg/L of ClO2 in less than 5 min. Higher concentration (20 mg/L) eliminated SARS-CoV-2 from sewage. ClO2 concentrations from 0.2 to 1.0 mg/L ensured at least a 99% viral reduction of AD40, HAV, Coxsackie B5 virus, and other enteric viruses in less than 30 min. Considering bloodborne viruses, 30 mg/L of ClO2 can eliminate them in 5 min. Bloodborne viruses (HIV-1, HCV, and HBV) may be completely eliminated from medical devices and human fluids after a treatment with 30 mg/L of ClO2 for 30 min. In conclusion, ClO2 is a versatile virucidal agent suitable for different environmental matrices.

3.
Int J Environ Res Public Health ; 17(21)2020 Nov 04.
Article in English | MEDLINE | ID: covidwho-908896

ABSTRACT

Microbiological surveillance carried out in order to verify the effectiveness of endoscope reprocessing does not include the research of viruses, although endoscopes may be associated with the transmission of viral infections. This paper reports the experience of the University Hospital of Pisa in managing the risk from severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) during an endoscopy. A review of the reprocessing procedure was conducted to assess whether improvement actions were needed. To verify the reprocessing efficacy, a virological analysis was conducted both before and after the procedure. Five bronchoscopes and 11 digestive endoscopes (6 gastroscopes and 5 colonoscopes) were sampled. The liquid samples were subjected to concentration through the use of the Macrosep Advance Centrifugal Devices (PALL Life Sciences, Port Washington, NY, USA) and subsequently analyzed using the cobas® SARS-CoV-2 Test (Roche Diagnostics, Basel, Switzerland), together with eSwab 490 CE COPAN swabs (COPAN, Brescia, Italy), which were used to sample surfaces. In accordance with the first ordinance regarding the coronavirus disease 2019 (COVID-19) emergency issued by the Tuscany Region in March 2020, a procedure dedicated to the management of the COVID-19 emergency in endoscopic practices was prepared, including the reprocessing of endoscopes. The virological analysis carried out on samples collected from endoscopes after reprocessing gave negative results, as well as on samples collected on the endoscopy column surfaces and the two washer-disinfectors that were dedicated to COVID-19 patients. The improvement in endoscope reprocessing implemented during the COVID-19 emergency was effective in ensuring the absence of SARS-CoV-2, thus reducing the risk of infections after an endoscopy on COVID-19 patients.


Subject(s)
Coronavirus Infections/prevention & control , Disinfection/standards , Endoscopy/instrumentation , Equipment Contamination/prevention & control , Pandemics/prevention & control , Pneumonia, Viral/prevention & control , Betacoronavirus , COVID-19 , Humans , Italy , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL